Syringes filling system with high precision
Hygienic design
Machine designed to fill syringes with fine powders for medical use: The syringe is suspended on a hand tool attached to the precision scales (0.01g). These scales are built into the casing of the machine for protection and this facilitates cleaning. Different types of syringes are used with many powders.
Résults : Filling 20µm fine powder with a 2A class feeder. Standard deviation: 0.01 gram for a set point of 6 grams.

Pictures:
 |

|
 |
 |
Syringe filling system designed according to hygienic standards. The powder packaging is used as a storage hopper of the feeder, to avoid contamination.
|
►MCPI weighing controllers for an easier operation and a better process control 